Global Finishing Solutions booth panel fault codes
What all 68 Global Finishing Solutions booth panel fault codes mean, in plain words, with a risk grade for each. These come from the manufacturer's own manual. The fix for each one is in WERCS Diagnose.
Get the fixes · plans from $49/moUpdated July 22, 2026
| Code | What it means | Risk |
|---|---|---|
| 1 | FIRE PROTECTION TRIPPED The fire alarm input is indicating an active alarm condition, stopping the booth. | RED |
| 2 | E-STOP PRESSED The emergency stop was pushed or has faulty wiring, which immediately shuts down the booth. | RED |
| 3 | EXHAUSET VFD OL FAULT The exhaust drive lost its run status or failed to indicate it was running after receiving a run command. | RED |
| 4 | INTAKE VFD OL FAULT The intake drive lost its run status or failed to indicate it was running after receiving a run command. | RED |
| 5 | DRIVE COMMUNICATIONS FAULT A motor drive has lost communication with the programmable logic controller, stopping operation. | RED |
| 6 | BURNER AIR NOT FLOWING The burner airflow switch failed to prove airflow or unexpectedly lost its proven status. | RED |
| 7 | BURNER FAIL TO START The burner failed to light due to an issue with the relay wiring or airflow request. | RED |
| 8 | FLAME FAILURE The flame safety relay has an alarm, which locks out the burner and stops the booth. | RED |
| 9 | BURNER GAS PRESSURE FAULT The system detected low or high gas pressure, which locks out the burner and stops the booth. | RED |
| #2 | Estop Pressed An emergency stop button is pressed, which immediately shuts down the booth equipment. | RED |
| #4 | Fire Alarm Active The fire alarm input is active, which shuts down the booth for safety. | RED |
| 10 | BURNER HIGH TEMP LIMIT FAULT The burner became too hot and tripped the high temperature switch, shutting down the heat. | RED |
| 11 | BOOTH NEGATIVE PRESSURE The booth has developed negative pressure, which stops the equipment from operating safely. | RED |
| 12 | EXHAUST VFD ALARM The exhaust drive lost its run status due to an internal error, blown fuse, or wiring fault. | RED |
| 13 | INTAKE VFD ALARM The intake drive lost its run status due to an internal error, blown fuse, or wiring fault. | RED |
| 14 | AMU IN TEST The air makeup unit service switches are currently in the on position, preventing normal operation. | GREEN |
| 15 | EXHAUST AIR FLOW FAULT The exhaust fan stopped running due to faulty hardware, broken belts, or a wiring issue. | RED |
| 16 | FAIL TO REACH TEMP IN CURE MODE The booth failed to reach the target temperature during the cure mode, which interrupts the curing process. | RED |
| 17 | TEMPERATURE PROBE FAULT The temperature probe is not reading, which prevents the booth from monitoring heat levels. | RED |
| #29 | Internal Software Error An internal software error occurred, preventing the booth control panel from operating normally. | RED |
| F01 | Emergency Stop The emergency stop pushbutton was pressed or has faulty wiring, which immediately shuts down the booth. | RED |
| F02 | Negative Pressure Limit The booth pressure feedback has exceeded the set negative pressure limit, which stops the booth from operating. | RED |
| F03 | Low Temperature Limit The temperature feedback dropped below forty degrees for five minutes while the booth was operating. | YELLOW |
| F04 | Fire Supp Type Config The fire suppression system is not configured in the maintenance settings, preventing normal operation. | RED |
| F05 | Exhaust Low Air Flow The exhaust fan drive indicated it was running, but the airflow switch failed to prove airflow within the required time. | RED |
| F06 | Recirc Damper Position The recirculation damper failed to indicate a closed position while the booth was operating. | YELLOW |
| F07 | Recirc Fresh Air Ratio Insufficient fresh air was introduced during the cure cycle, which causes the booth to fault. | RED |
| F08 | Fresh Air Damper Position The fresh air damper failed to indicate an open position while the booth was operating. | RED |
| F09 | Burner Flame Failure The flame safety relay has triggered an alarm, indicating a burner flame failure. | RED |
| F10 | Intake Motor Run Feedback The intake drive lost its run status or failed to indicate it was running after receiving a run command. | YELLOW |
| F11 | Exhaust Motor Run Feedback The exhaust drive lost its run status or failed to indicate it was running after receiving a run command. | RED |
| F12 | Intake Damper Position The intake damper failed to indicate an open position while the booth was operating outside of cure mode. | RED |
| F13 | Burner Air Flow The burner airflow switch failed to prove airflow within the set time or unexpectedly lost its proven status. | RED |
| F33 | Fire Alarm The fire alarm input is indicating an active alarm condition because the okay signal was lost. | RED |
| W01 | Over Temperature The booth temperature exceeded the setpoint plus the over temperature tolerance for the programmed time, triggering a warning. | RED |
| W02 | Under Temperature The booth temperature dropped below the setpoint minus the under temperature tolerance for the programmed time, triggering a warning. | GREEN |
| W03 | Burner Unlit The burner failed to ignite within the set time or unexpectedly lost its flame, causing the heating system to fault. | RED |
| W04 | Burner Air Flow The burner airflow switch failed to prove airflow within the set time or unexpectedly lost its proven status. | GREEN |
| W05 | Recirc Damper Position The recirculation damper failed to indicate a closed position, triggering a warning level alert. | GREEN |
| W06 | Fresh Air Damper Position The fresh air damper failed to indicate an open position, triggering a warning level alert. | GREEN |
| W07 | I/O Force(s) Active An input or output is currently being forced on the programmable logic controller, triggering a warning. | RED |
| W08 | Fan Service Switch Detected The fan service switch is currently in the on position at the air makeup unit. | GREEN |
| W09 | Burner Service Switch Detected The burner service switch is currently in the on position at the air makeup unit. | GREEN |
| W10 | Man Door Open The personnel door remained open longer than the allowed time delay while the booth was operating. | RED |
| W11 | Product Door Open The product door was opened while the booth was actively operating, triggering a warning. | RED |
| W12 | Man Door Open The personnel door was opened during the cure cycle, which interrupts the process and requires an interface acknowledgement to put the booth back into cure mode. | RED |
| W13 | Prod Door Open The product door was opened during the cure cycle, which interrupts the process and requires an interface acknowledgement to put the booth back into cure mode. | RED |
| W14 | Light Lens Loop A light lens is loose or has been removed, which prevents the booth from operating. | RED |
| W15 | Intake Dirty Filter The intake filter is indicating it is dirty and restricting airflow. | GREEN |
| W16 | REVO Power Rail Low Pressure The power rail is not adequately pressurized to keep overspray out, which stops the booth from running. | GREEN |
| W17 | REVO Unit not at home position The unit is not at its home position while the booth is operating outside of flash mode. | GREEN |
| W18 | REVO Door Open The unit doors are open while the booth is operating outside of flash mode. | GREEN |
| W19 | REVO Power Rail On The power rail indicates it is powered when not commanded on, triggering a system warning. | RED |
| W20 | Cure Timer Forced Start The temperature feedback failed to reach the required tolerance within ten minutes of entering cure or after a door was opened, forcing the timer to start. | GREEN |
| W21 | Intake Damper Position The intake damper failed to indicate an open position before the warning delay timer expired. | GREEN |
| W22 | Cure Aborted The burner flame was lost during the cure cycle, which causes the cure process to abort. | RED |
| #x032 | Burner Box # - Purge Interlock Relay malfunction The purge interlock relay on the numbered burner box malfunctioned, preventing the burner from starting. | RED |
| #x448 | Burner Box # - Burner - Flame Failure The numbered burner box failed to prove flame, causing the burner to lock out. | RED |
| #x449 | Burner Box # - Burner - Purge Timeout The numbered burner box timed out during the purge cycle, which stops the burner and interrupts the flame safety sequence. | RED |
| #x450 | Burner Box # - Burner - Flame Lost The numbered burner box lost its flame during operation, causing the burner to shut down. | RED |
| #x451 | Burner Box # - Burner - Burner Unextinguished The numbered burner box detected a flame when it was supposed to be off, triggering a safety lockout. | RED |
| #x452 | Burner Box # - Burner - Low Gas Pressure The numbered burner box detected low gas pressure, which locks out the burner. | RED |
| #x453 | Burner Box # - Burner - High Gas Pressure The numbered burner box detected high gas pressure, which locks out the burner. | RED |
| #x455 | Burner Box # - Burner - High Temperature Limit Tripped The high temperature limit on the numbered burner box tripped, shutting down the burner to prevent overheating. | RED |
| DELUXE_DIRTY_FILTER | Dirty Filter The booth filters are loaded with overspray, which disables the air solenoid valve. | GREEN |
| DELUXE_FIRE_SYSTEM_FAULT | Fire System Fault The fire alarm input indicates an active alarm condition, which shuts down the booth. | RED |
| DELUXE_VENTILATION_FAULT | Ventilation Fault A variable frequency drive faulted, which stops the ventilation fans from running. | RED |
| DELUXE_AIR_SOLENOID_DISABLED | Air Solenoid Valve Disabled/No Compressed Air The air solenoid valve is disabled due to a lack of compressed air or an open safety interlock, stopping painting operations. | GREEN |
Every code comes from the manufacturer's own manual. Subscribers see which manual and page.