Burner controls, ignition and flame safeguards

Satronic / Honeywell DKO 970/972 Oil Burner Control fault codes

What all 5 Satronic / Honeywell DKO 970/972 Oil Burner Control fault codes mean, in plain words, with a risk grade for each. These come from the manufacturer's own manual. The fix for each one is in WERCS Diagnose.

CodeWhat it meansRisk
1 short + 1 long flashFlash-Code: 1 short then 1 long pulse (internal fuse defect)
The oil burner control locks out due to an internal fuse or control box defect.
YELLOW
1 short + 2 long flashesFlash-Code: 1 short then 2 long pulses (low mains voltage)
The mains voltage dropped too low, causing the burner control box to lock out until voltage recovers.
GREEN
1 short + 4 long flashesFlash-Code: 1 short then 4 long pulses
The oil burner control locks out because a flame was not established within the safety time.
RED
2 short + 3 long flashesFlash-Code: 2 short then 3 long pulses (stray light)
The oil burner control locks out because it detects stray light during the monitored phase.
RED
2 short + 8 long flashesFlash-Code: 2 short then 8 long pulses (manual/external lockout)
The oil burner control is deliberately placed into a manual or external lockout state, stopping operation.
RED