Burner controls, ignition and flame safeguards

White-Rodgers 50E47-843 Hot Surface Ignition fault codes

What all 7 White-Rodgers 50E47-843 Hot Surface Ignition fault codes mean, in plain words, with a risk grade for each. These come from the manufacturer's own manual. The fix for each one is in WERCS Diagnose.

Get the fixes · plans from $49/moUpdated November 4, 2026
CodeWhat it meansRisk
OFFOFF
An internal failure has occurred, causing the ignition control to shut down the burner completely.
YELLOW
Red 1 FlashRed 1 Flash
The maximum number of ignition retries was exceeded, forcing the burner into a lockout state.
RED
Red 2 FlashRed 2 Flash
The maximum number of ignition recycles was exceeded, forcing the burner into a lockout state.
RED
Red Solid OnRed Solid On
A miswired gas valve or internal error was detected, causing the burner to lock out.
RED
Red Rapid FlashRed Rapid Flash
A flame was sensed when none was expected, forcing the control into a lockout state.
RED
Green Rapid FlashingGreen Rapid Flashing
A weak flame signal is detected, which can cause the burner to drop out unexpectedly.
GREEN
Yellow Rapid FlashingYellow Rapid Flashing
Improper electrical polarity was detected, preventing the ignition control from operating the burner system safely.
YELLOW