Siemens SINAMICS V20 VFD fault codes

What all 54 Siemens SINAMICS V20 VFD fault codes mean, in plain words, with a risk grade for each. These come from the manufacturer's own manual. The fix for each one is in WERCS Diagnose.

Get the fixes · plans from $49/moUpdated November 4, 2026
CodeWhat it meansRisk
F1Overcurrent
The drive has detected an overcurrent condition, which causes the equipment to stop running immediately.
RED
F2Overvoltage
The drive has detected an overvoltage condition, which forces the booth equipment to shut down.
YELLOW
F3Undervoltage
The drive has detected an undervoltage condition, causing the booth equipment to stop operating.
YELLOW
F4Converter overtemperature
The converter has reached an overtemperature condition, which causes the drive to stop the booth equipment.
YELLOW
F5Converter I2t
The converter has exceeded its thermal current limit, causing the drive to stop the equipment.
YELLOW
F6Chip temperature rise exceeds critical levels
The internal chip temperature rise has exceeded critical levels, which forces the drive to stop the booth.
YELLOW
F11Motor overtemperature
The motor has reached an overtemperature condition, causing the drive to shut down the booth equipment.
YELLOW
F12Converter temperature signal lost
The converter heat sink temperature sensor has a broken wire, which causes the drive to stop the equipment.
YELLOW
F20DC ripple too high
The calculated direct current ripple level has exceeded the safe threshold, causing the drive to stop the booth.
RED
F23Output current ripple too high
The calculated output ripple level has exceeded the safe threshold, which forces the drive to stop the equipment.
RED
F35Maximum number of auto restart attempts exceeded
The auto restart attempts exceeded the maximum allowed value, which causes the drive to fault and stop trying to start.
YELLOW
F41Motor data identification failure
The motor data identification process has failed, which prevents the drive from starting the booth equipment.
YELLOW
F51Parameter EEPROM fault
A read or write failure occurred while accessing the memory, which prevents the drive from operating the booth.
YELLOW
F52Converter software fault
A read failure for converter information or invalid data has occurred, causing the drive to stop the equipment.
YELLOW
F60Asic timeout
An internal communications failure has occurred, which forces the drive to shut down the booth equipment.
YELLOW
F61SD card parameter cloning failed
The parameter cloning process has failed, which prevents the drive from starting the booth equipment.
YELLOW
F62Parameter cloning contents invalid
The cloning file exists but contains invalid data, which prevents the drive from operating the booth.
YELLOW
F63Parameter cloning contents incompatible
The cloning file exists but is the wrong converter type, preventing the drive from loading the parameters.
YELLOW
F64Converter attempted to do an automatic clone during startup
The required clone file is missing from the correct directory, which prevents the drive from starting the equipment.
YELLOW
F70I/O Extension Module communication fault
Communication is no longer established with the extension module, causing the drive to stop the booth equipment.
YELLOW
F71USS setpoint fault (on RS232)
The drive is receiving no setpoint values during the telegram off time, which causes the equipment to stop.
YELLOW
F72USS/MODBUS setpoint fault (on RS485)
The drive is missing setpoint values from the communication network, causing the booth equipment to shut down.
YELLOW
F80Signal lost on analog input
The signal has been lost on the analog input, which forces the drive to stop the booth equipment.
YELLOW
F85External fault
An external fault has been triggered via the command input, causing the drive to stop the equipment.
YELLOW
A501Current limit
The drive has reached its current limit, which triggers a warning but allows the booth equipment to keep running.
GREEN
A502Overvoltage limit
The overvoltage limit has been reached during ramp down, which triggers a warning without stopping the booth equipment.
GREEN
A503Undervoltage limit
The drive has reached its undervoltage limit, which generates a warning while the booth equipment continues to operate.
GREEN
A504Converter overtemperature
The converter temperature warning level is exceeded, which reduces the output frequency while the booth equipment continues running.
GREEN
A505Converter I2t
The converter thermal warning level has been exceeded, which reduces the current while the booth equipment keeps running.
GREEN
A506IGBT junction temperature rise warning
The temperature difference between the heat sink and transistor exceeds warning limits, which alerts the operator without stopping the booth.
GREEN
A507Converter temperature signal lost
The converter heat sink temperature signal has been lost, which triggers a warning but allows the equipment to run.
GREEN
A511Motor overtemperature I2t
The motor is overloaded due to high load cycles or steps, which stops the drive to prevent damage.
GREEN
A523Output current ripple too high
The calculated output ripple level has exceeded the safe threshold, which triggers a warning without stopping the booth equipment.
RED
A535Braking resistor overload
The braking energy is too large for the resistor, which generates a warning while the booth equipment keeps running.
GREEN
A541Motor data identification active
The motor data identification process is currently running, which keeps the drive busy before the booth can start.
GREEN
A600RTOS overrun warning
An internal time slice overrun has occurred, which triggers a warning while the drive continues to operate the booth.
GREEN
A910Vdc_max controller deactivated
The maximum voltage controller has deactivated due to high supply voltage, which triggers a warning without stopping the booth.
GREEN
A911Vdc_max controller active
The maximum voltage controller is actively keeping the direct current link voltage below the specified limit while the booth runs.
GREEN
A912Vdc_min controller active
The minimum voltage controller has activated because the direct current link voltage fell below the specified limit during operation.
GREEN
A921Analog output parameters not set properly
The analog output parameters are set to identical values, which produces illogical results and triggers a warning on the drive.
GREEN
A922No load applied to converter
There is no load applied to the converter, which causes some functions to operate differently while the booth runs.
GREEN
A923Both JOG left and JOG right are requested
Both left and right jog commands have been requested simultaneously, which freezes the output frequency at its current value.
GREEN
A930Cavitation protection warn
Conditions exist for possible pump cavitation damage, which triggers a warning while the booth equipment continues to operate.
GREEN
A936PID autotuning active
The proportional integral derivative autotuning process is currently running, which keeps the drive busy before normal booth operation begins.
GREEN
A952Load monitoring warning
The motor load conditions indicate a potential belt failure or mechanical fault, which triggers a warning without stopping the booth.
GREEN
F100Watchdog reset
A software error has occurred within the drive, which forces the booth equipment to shut down immediately.
YELLOW
F101Stack overflow
A software error or processor failure has occurred, causing the drive to stop operating the booth equipment.
YELLOW
F200Script error
The internal converter program script has stopped running due to errors, which causes the drive to shut down.
YELLOW
F221PID feedback below minimum value
The proportional integral derivative feedback has fallen below the minimum value, causing the drive to stop the equipment.
YELLOW
F222PID feedback above maximum value
The proportional integral derivative feedback has exceeded the maximum value, which forces the drive to stop the booth.
YELLOW
F350Configuration vector for the converter failed
The hardware does not match the programmed configuration vector, which causes the drive to trip and stop the booth.
YELLOW
F395Acceptance test/confirmation pending
An acceptance test is pending after a startup clone or memory read error, which prevents the drive from starting.
YELLOW
F410Cavitation protection failure
Conditions exist for potential pump cavitation damage due to insufficient fluid flow, causing the drive to stop the equipment.
YELLOW
F452Load monitoring trip
The motor load conditions indicate a belt failure or mechanical fault, which forces the drive to stop the booth.
YELLOW

Every code comes from the manufacturer's own manual. Subscribers see which manual and page.